Electrical ControlCabinet with Air conditioning

空调电柜系统-安全.jpg

Features:

1.The collected temperature and exhaust temperature of each chamber are used for monitoring
2. When the chamber's temperature exceeds the warning temperature,an alarm will be given, and “the chamber'stemperature is too high" warning will be given
3.When the chamber temperature and exhaust temperature continue to rise above 10 ℃ on the warning temperature, the firealarm will be triggered
4.When a fire alarm is triggered, the program will automatically turn off the exhaust fan, circulating fan and heating burner,and automatically open the steam fire extinguishing valve to extinguish the fire, and the alarm light will be on and call
5.When the fire alarm of the chamber is relieved, the fire extinguishing steam valve can be closed only by manually pressingthe fire reset
6.The steam fire extinguishing valve can also be opened manually without fire alarm